Q2. Setting and realizing of anti-theft function. |
|
| |
| |
Two codes for anti-theft functions 4093 and 4094, audio guide unit will alarm to remind visitors return back it when |
|
| |
triggered by the two codes. |
|
| |
Alarm time can be set from 0-30 minutes by code 4093 or 4094. (This parameter should be set on WD-900) |
|
| |
|
|
| |
Setting of immediate alarm |
|
| |
⑴. Set alarm time as 0 minute; |
|
| |
⑵. Audio guide will alarm immediately once it entered trigger zone of 4093 or 4094. |
|
| |
|
|
| |
Setting of delayed alarm |
|
| |
This setting is always used for only alarm when exiting, no alarm when entering. |
|
| |
Following conditions should be met to set delayed alarm, audio guide will alarm after the setting time. |
|
| |
⑴. Alarm time was set in the range of 1-30 minutes; |
|
| |
⑵. AG-600 should leave this trigger zone after it triggered by codes 4093 or 4094; |
|
| |
⑶. Also, only the AG-600 has been used will realize delayed alarm, one of the two conditions must be met: |
|
| |
① Audio guide has already been trigger played automatically. |
|
| |
② Audio guide has played 3 complete audios by keypad manually.(Ignore this, if your model is AG-600N) |
|