南京索莱电子科技有限公司
 
 
  Q2. Setting and realizing of anti-theft function.  
 
  Two codes for anti-theft functions 4093 and 4094, audio guide unit will alarm to remind visitors return back it when  
  triggered by the two codes.  
  Alarm time can be set from 0-30 minutes by code 4093 or 4094. (This parameter should be set on WD-900)  
     
  Setting of immediate alarm  
  . Set alarm time as 0 minute;  
  . Audio guide will alarm immediately once it entered trigger zone of 4093 or 4094.  
     
  Setting of delayed alarm  
  This setting is always used for only alarm when exiting, no alarm when entering.  
  Following conditions should be met to set delayed alarm, audio guide will alarm after the setting time.  
  . Alarm time was set in the range of 1-30 minutes;  
  . AG-600 should leave this trigger zone after it triggered by codes 4093 or 4094;  
  . Also, only the AG-600 has been used will realize delayed alarm, one of the two conditions must be met:  
  Audio guide has already been trigger played automatically.  
  Audio guide has played 3 complete audios by keypad manually.(Ignore this, if your model is AG-600N)  
 
 
 
 
 
Copyright (C) 2007-2018 SOOLAI. All Rights Reserved.
SitemapLegalContact
南京索莱电子科技有限公司-索莱SOOLAI SOOLAI ELECTRONICS CO.,LTD 导游讲解设备、导游系统、无线导览专用车载充电器 导览系统、导游系统、同传系统专用挂绳